fbpx

Welcome | log in

    • Online double conversion
    • Wide input voltage range (110 ~ 300 Vac)
    • Input power factor: 0.99 (With PFC)
    • Output power factor: 1.0
    • Optional charging current either 1A or 2A (2A charging current for two groups of installed batteries)
    • 50 Hz / 60 Hz frequency converter mode
    • Emergency power off function (EPO)
    • ECO mode support
    • Generator compatible
    • Optional Communication ports: SNMP, USB, RS232
    • Smart battery charging design for optimized battery performance
    • Supports lithium batteries and BMS
    • Selectable output voltage: 200, 208, 220, 230, 240 Vac
    • Low priority load disconnection function
    • N+X parallel redundancy
    • Online double conversion with DSP control
    • Harmonic input current: <5%
    • PF at different battery quantity installed: 16 batteries:
      • 0.7 PF 18 batteries:
      • 0.8 PF
      • 20 batteries: 0.9 PF
    • Wide input voltage range: 208 ~ 478 Vac
    • Wide input frequency range:
      • 50 Hz: 45 ~ 55 Hz
      • 60 Hz: 54 ~ 66 Hz
    • Supports generator input
    • Supports economic (ECO) operation mode
    • Self-testing at startup of UPS
    • Optional: SNMP card/relay card/parallel board
    • Supports cold start
     
    • N+X parallel redundancy
    • Online double conversion with DSP control
    • Harmonic input current: <5%
    • PF at different battery quantity installed: 16 batteries:
      • 0.7 PF 18 batteries:
      • 0.8 PF
      • 20 batteries: 0.9 PF
    • Wide input voltage range: 208 ~ 478 Vac
    • Wide input frequency range:
      • 50 Hz: 45 ~ 55 Hz
      • 60 Hz: 54 ~ 66 Hz
    • Supports generator input
    • Supports economic (ECO) operation mode
    • Self-testing at startup of UPS
    • Optional: SNMP card/relay card/parallel board
    • Supports cold start
     
    • Online- Double conversion
    • Output transfer time is Oms
    • PFC technology
    • Full digital control (DS P)
    • Output power factor: 0.9
    • Input current harmonic: 3%
    • ECO function
    • Charging/Rectifier/Inverter fully digital control technology
    • Optimization battery group, the quantity of battery: 10 - 30K(16/18/20 pcs optional) 40 - 80K (32/34/36/38/40 pcs optional)
    • Wide input voltage range: 208-478Vac
    • Wide input frequency range: 40- 70Hz
    • DC start
    • Communication port: USB/RS232 / RS485 / Parallel port / dry contact
    • Options: SNMP card/Relay card
    • LCD / LED double display
    • Intelligent charging management
    • EPO function
    • Common battery group
    • The output can meet 100% unbalanced load
    • N+X parallel redundancy
    • Online double conversion with DSP control
    • Input current harmonic: <3%
    • High output power factor: 0.9 PF
    • Wide input voltage range: 120 ~ 276 Vac
    • Wide input frequency range:
      • 50 Hz: 45 ~ 55 Hz
      • 60 Hz: 54 ~ 66 Hz
    • Supports generator input
    • ECO mode
    • Self-testing at startup of UPS
    • Optional: SNMP card/relay card/parallel card
     

Title

Go to Top